AvaSpec-1024
The AvaSpec-1024 Fibre Optic Spectrometer is based on the AvaBench-75 symmetrical Czerny-Turner design with 1024 pixel CMOS Detector Array. The spectrometer has a fibre optic entrance connector (as standard SMA - other types are possible), collimating and focusing mirror and diffractional grating. A choice of 15 different gratings with different dispersion and blaze angles enable applications in the 200-1100nm range. The AvaSpec-1024 can be delivered with 2 different electronic platforms - either with USB1.1 or the new USB2.0 interface, both with 14bit A/D converter.
The AvaSpec-1024 is especially suitable for low noise application with good resolution. Digital IO ports enable external triggering and control of a shutter and pulsed light sources from the Avantes line of instruments.
The AvaSpec-1024 is also available as a dual or multiple channel instrument (up to 8 channels), where all spectra are taken simultaneously.
The AvaSpec-1024 is supplied as standard with AvaSoft-BASIC, a complete manual, USB interface cable and will run on USB power (-SPU option). However, a PS-12V/1.0A power supply can be ordered separately for mains power use if this is preferred. In this case, the user will then have both options available. AvaSoft-FULL and application specific software can be ordered separately from the AvaSoft software library.
The new AvaSpec-1024-USB2 has a USB2 interface with ultrafast datasampling of 450 spectra per second, data transfer in 2.2msec and supports analog inputs and outputs.
Optional Bluetooth® (-BT) communication and an SDRAM card for on-board saving of spectra can be added.
For USB2 platform devices, multiple (up to 127) spectrometers with different detector types can be externally coupled (for further information, please view the section 'Multichannel Spectrometers').
For further information and assistance, please contact us.
Technical Details
|
Spectrometer Platform |
AvaSpec-1024 |
AvaSpec-1024-USB2 |
|
Optical Bench |
Symmetrical Czerny-Turner, 75mm focal length | |
|
Wavelength Range |
200-1100nm | |
|
Resolution |
0.07-20nm, depending on configuration | |
|
Stray Light |
<0.1% | |
|
Sensitivity (AvaLight-HAL, 8µm Fibre) |
30 counts/µW per ms integration time | |
|
Detector |
CMOS Linear Array, 1024 pixels | |
|
Signal/Noise |
2000:1 | |
|
AD Converter |
14 bit, 330kHz |
16 bit, 500kHz |
|
Integration time |
4msec – 60sec |
2.2msec – 10min |
|
Interface |
USB1.1, 12Mbps RS232, 115,200bps |
USB2.0 high speed, 480Mbps RS232, 115,200bps |
|
Sample Speed (with on-board averaging) |
12msec/scan |
2.2msec/scan |
|
Data Transfer Speed |
12-20ms/scan (depending on pixel # transferred) |
2.2ms/scan |
|
Digital IO |
DB15 connector, 2 digital in, 12 digital out |
HD26 connector, 2 analogue in, 2 analogue out, 3 digital in, 12 digital out, trigger sync |
|
Power Supply |
12VDC, reverse polarity protection, 160mA (PS12V/1.0A) or 5VDC USB power |
Default USB power, 440mA, or with SPU2 external 12 VDC, 440mA |
|
Dimensions/Weight |
175x110x44mm (1 channel), 716g. 175x165x85mm (2 channel), 1700g. |
175x110x44mm (1 channel), 716g. |
Grating Selection Chart for the AvaSpec-1024
|
Use |
Useable range |
Spectral range |
Lines/mm |
Blaze (nm) |
Order code |
|
UV/VIS/NIR |
200-1100nm* |
900nm* |
300 |
300 |
UA |
|
UV/VIS |
200-850nm |
450nm |
600 |
250 |
UB |
|
UV |
200-750nm |
220nm |
1200 |
250 |
UC |
|
UV |
200-650nm |
160nm |
1800 |
250 |
UD |
|
UV |
200-580nm |
100nm |
2400 |
250 |
UE |
|
UV |
220-400nm |
50nm |
3600 |
250 |
UF |
|
UV/VIS |
250-850nm |
450nm |
600 |
370 |
BB |
|
VIS/NIR |
300-1100nm* |
800nm* |
300 |
500 |
VA |
|
VIS |
360-1000nm |
450nm |
600 |
500 |
VB |
|
VIS |
300-800nm |
220nm |
1200 |
500 |
VC |
|
VIS |
350-750nm |
160nm |
1800 |
500 |
VD |
|
NIR |
500-1050nm |
450nm |
600 |
750 |
NB |
|
NIR |
500-1000nm |
200nm |
1200 |
750 |
NC |
|
NIR |
600-1100nm* |
500nm* |
300 |
1000 |
IA |
|
NIR |
600-1100nm |
450nm |
600 |
1000 |
IB |
Resolution Chart for the AvaSpec-1024
|
|
Slit Size (µm) | ||||
|
Grating (l/mm) |
25 |
50 |
100 |
200 |
500 |
|
300l/mm |
1.2 |
2.4 |
4.3 |
8.0 |
20.0 |
|
600l/mm |
0.8 |
1.2 |
2.1 |
4.1 |
10.0 |
|
1200l/mm |
0.4 |
0.5 |
1.0 |
2.0 |
5.0 |
|
1800l/mm |
0.3 |
0.4 |
0.8 |
1.4 |
3.5 |
|
2400l/mm |
0.2 |
0.25 |
0.5 |
1.0 |
2.5 |
|
3600l/mm |
0.15 |
0.20 |
0.4 |
0.6 |
1.5 |
|
|
FWHM Resolution (nm) | ||||
Ordering Information
|
Part Number |
Description |
|
AvaSpec-1024 |
Fibre Optic Spectrometer, 75mm AvaBench, 1024 pixel CMOS detector, self powered USB1.1, USB1.1/RS-232 interface, includes AvaSoft-BASIC, USB cable. Please specify grating, wavelength range and options |
|
AvaSpec-1024-USB2 |
Fibre Optic Spectrometer, 75mm AvaBench, 1024 pixel CMOS detector, self powered high speed USB2, USB2/RS-232 interface, includes AvaSoft-BASIC, USB cable. Please specify grating, wavelength range and options |
|
AvaSpec-1024-2 |
Dual Channel Fibre Optic Spectrometer, 2x 75mm AvaBench, 1024 pixel CMOS detectors, self powered USB1.1, USB1.1/RS-232 interface, includes AvaSoft-BASIC, USB cable. For both channels, please specify grating, wavelength range and options |
|
Options | |
|
-SPU |
Includes switch for self powered USB1 (external power supply required for RS-232 interface) |
|
-SPU2 |
Includes switch for self powered USB2 (external power supply required for RS-232 interface) |
|
BT |
Bluetooth® interface for USB2 platform only, includes antenna |
|
SDXXX |
Internal xxx MB SD card for on-board data saving, for USB2 platform only |
|
SLIT-xx |
Slit size, please specify xx = 10, 25, 50, 100, 200 or 500µm |
|
OSF-YYY |
Order sorting filter for reduction of 2nd order effects, please specify yyy = 385, 475, 515, 550 or 590nm |
|
OSC |
Order sorting coating with 590nm longpass filter for gratings VA, BB and VB, for the AvaSpec-1024 |
|
OSC-UA |
Order sorting coating with 350nm and 590nm longpass filter for grating UA, for the AvaSpec-1024 |
|
OSC-UB |
Order sorting coating with 350nm and 590nm longpass filter for grating UB, for the AvaSpec-1024 |