AvaSpec-3648
The AvaSpec-3648 Fibre Optic Spectrometer is based on the AvaBench-75 symmetrical Czerny-Turner design with 3648 pixel CCD Detector Array. The spectrometer has a fibre optic entrance connector (as standard SMA - other types are possible), collimating and focusing mirror and diffractional grating. A choice of 15 different gratings with different dispersion and blaze angles enable applications in the 200-1100nm range. The AvaSpec-3648 is delivered with a high speed USB2 interface and 14bit A/D converter.The AvaSpec-3648 is especially suitable for low light level and high resolution applications. An optional detector coating enhances the CCD performance for the UV range and a detector collection lens offers high sensitivity. Digital IO ports enable external triggering and control of a shutter and pulsed light sources from the Avantes line of instruments.
The AvaSpec-3648 is also available as a multiple channel instrument (up to 8 channels), where all spectra are taken simultaneously.
The AvaSpec-3648 is supplied as standard with AvaSoft-BASIC, a complete manual, USB interface cable and will run on USB power (-SPU option). However, a PS-12V/1.0A power supply can be ordered separately for mains power use if this is preferred. In this case, the user will then have both options available. AvaSoft-FULL and application specific software can be ordered separately from the AvaSoft software library.
The AvaSpec-3648 has a USB2 interface with ultrafast datasampling of 270 spectra per second, data transfer in 3.7msec and supports analog inputs and outputs.
Optional Bluetooth® (-BT) communication and an SDRAM card for on-board saving of spectra can be added.
For USB2 platform devices, multiple (up to 127) spectrometers with different detector types can be externally coupled (for further information, please view the section 'Multichannel Spectrometers').
For further information and assistance, please contact us.
Technical Details
|
Spectrometer Platform |
AvaSpec-3648-USB2 |
|
Optical Bench |
Symmetrical Czerny-Turner, 75mm focal length |
|
Wavelength Range |
200-1100nm |
|
Resolution |
0.25-20nm, depending on configuration |
|
Stray Light |
<0.1% |
|
Sensitivity (AvaLight-HAL, 8µm Fibre) |
12000 counts/µW per ms integration time |
|
Detector |
CCD Linear Array, 3648 pixels |
|
Signal/Noise |
300:1 |
|
AD Converter |
16 bit, 1MHz |
|
Integration time |
10µs-10min |
|
Interface |
USB2.0 high speed, 480Mbps or RS232, 115,200bps |
|
Sample Speed (with on-board averaging) |
3.7msec/scan |
|
Data Transfer Speed |
3.7mses/scan |
|
Digital IO |
HD26 connector, 2 analogue in, 2 analogue out, 3 digital in, 12 digital out, trigger sync |
|
Power Supply |
Default USB power, 440mA, or with SPU2 external 12 VDC, 440mA |
|
Dimensions/Weight |
175x110x44mm (1 channel), 716g |
Grating Selection Chart for the AvaSpec-3648
|
Use |
Useable range |
Spectral range |
Lines/mm |
Blaze (nm) |
Order code |
|
UV/VIS/NIR |
200-1100nm** |
900nm** |
300 |
300 |
UA |
|
UV/VIS |
200-850nm |
520nm |
600 |
250 |
UB |
|
UV |
200-750nm |
250-220nm* |
1200 |
250 |
UC |
|
UV |
200-650nm |
165-145nm* |
1800 |
250 |
UD |
|
UV |
200-580nm |
115-70nm* |
2400 |
250 |
UE |
|
UV |
220-400nm |
75-50nm* |
3600 |
250 |
UF |
|
UV/VIS |
250-850nm |
520nm |
600 |
370 |
BB |
|
VIS/NIR |
300-1100nm** |
800nm** |
300 |
500 |
VA |
|
VIS |
360-1000nm |
500nm |
600 |
500 |
VB |
|
VIS |
300-800nm |
250-200nm* |
1200 |
500 |
VC |
|
VIS |
350-750nm |
145-100nm* |
1800 |
500 |
VD |
|
NIR |
500-1050nm |
500nm |
600 |
750 |
NB |
|
NIR |
500-1050nm |
220-150nm* |
1200 |
750 |
NC |
|
NIR |
600-1100nm** |
500nm** |
300 |
1000 |
IA |
|
NIR |
600-1100nm |
500nm |
600 |
1000 |
IB |
** Please note that not all 3648 pixels will be used for the useable range
Resolution Chart for the AvaSpec-3648
|
|
Slit Size (µm) | |||||
|
Grating (l/mm) |
10 |
25 |
50 |
100 |
200 |
500 |
|
300l/mm |
0.5 |
1.4 |
2.4 |
4.3 |
8.0 |
20.0 |
|
600l/mm |
0.25 |
0.7 |
1.2 |
2.1 |
4.1 |
10.0 |
|
1200l/mm |
0.07-0.13* |
0.2-0.3* |
0.4-0.6* |
0.7-1.0* |
1.4-2.0* |
3.3-4.8* |
|
1800l/mm |
0.05-0.08* |
0.12-0.21* |
0.2-0.36* |
0.4-0.7* |
0.7-1.4* |
1.7-3.3* |
|
2400l/mm |
0.04-0.07* |
0.08-0.15* |
0.14-0.25* |
0.3-0.5* |
0.5-0.9* |
1.2-2.2* |
|
3600l/mm |
0.25-0.04* |
0.07-0.10* |
0.11-0.16* |
0.2-0.3* |
0.4-0.6* |
0.9-1.4* |
|
|
FWHM Resolution (nm) | |||||
Ordering Information
|
Part Number |
Description |
|
AvaSpec-3648-USB2 |
Fibre Optic Spectrometer, 75mm AvaBench, 3648 pixel CCD detector, self powered high speed USB2.0, USB2.0/RS-232 interface, includes AvaSoft-BASIC, USB cable. Please specify grating, wavelength range and options |
|
AvaSpec-3648-SPU2 |
Fibre Optic Spectrometer, 75mm AvaBench, 3648 pixel CCD detector, self powered high speed USB2 including switch for selection of USB or external power, USB2/RS-232 interface, includes AvaSoft-BASIC, USB cable. Please specify grating, wavelength range and options |
|
Options | |
|
BT |
Bluetoothò interface for USB2 platform only, includes antenna |
|
SDXXX |
Internal xxx MB SD card for on-board data saving, for USB2 platform only |
|
DUV |
Deep UV detector coating, required for use <350nm/>150nm |
|
DCL-UV/VIS |
Detector collection lens to enhance sensitivity, Quartz, 200-1100nm |
|
SLIT-xx |
Slit size, please specify xx = 10, 25, 50, 100, 200 or 500µm |
|
OSF-YYY |
Order sorting filter for reduction of 2nd order effects, please specify yyy = 385, 475, 515, 550 or 590nm |
|
OSC |
Order sorting coating with 590nm longpass filter for gratings VA, BB and VB, for the AvaSpec-3648 |
|
OSC-UA |
Order sorting coating with 350nm and 590nm longpass filter for grating UA, for the AvaSpec-3648 |
|
OSC-UB |
Order sorting coating with 350nm and 590nm longpass filter for grating UB, for the AvaSpec-3648 |