Anglia Instruments Ltd

TE-Cooled Spectrometers

buy now

The AvaSpec-2048TEC is a special version of the AvaSpec-2048, where the Sony 2048 CCD detector is mounted on a one-stage Peltier cooling device.

This Peltier cooling element can reduce the temperature of the CCD chip by ca. 30 °C, improving the dynamic range by at least a factor of 10. As an additional benefit from the cooling, the dark noise is reduced by a factor of 2-3.

The above features enable the AvaSpec-2048TEC to be implemented in low light-level applications, such as fluorescence and Raman measurements, and where integration times of more than 5 seconds are needed.

The AvaSpec-2048TEC can be delivered as a single or dual channel instrument and has all the standard options, gratings and specifications as the standard AvaSpec-2048.

The AvaSpec-2048TEC is built into a desktop housing, has a cooling fan to actively ventilate the heatsink of the Peltier cooling element and an internal power supply.

For further information and assistance, please contact us.

Technical Details

Temperature Cooled CCD

DT = ca. -30°C vs ambient

Time to Stabilise

1-2 minutes

Dynamic Range improvement for it> 5 seconds

>Factor 10

Dark Noise improvement for it> 5 seconds

Factor 2-3

Peltier Cooling internal power supply

Ca. 3.0V, 4A

External power supply

100-240VAC, 30W

Dimensions

310x235x135mm (Desktop Housing)

Ordering Information

Part Number

Description

AvaSpec-2048-TEC

Thermo-Electric Cooled Fibre Optic Spectrometer, 75mm AvaBench, 2048 pixel TEC CCD detector, USB1.1/RS-232 interface, includes AvaSoft-BASIC and USB cable. Supplied in desktop housing. Please specify grating, wavelength range and options

AvaSpec-2048-TEC-2

Dual Channel Thermo-Electric Cooled Fibre Optic Spectrometer, 2x 75mm AvaBench, 2048 pixel TEC CCD detectors, USB1.1/RS-232 interface, includes AvaSoft-BASIC and USB cable. Supplied in desktop housing. Please specify grating, wavelength range and options for both channels

Options

DUV

Deep UV detector coating, required for use <350nm/>150nm

DCL-UV/VIS

Detector collection lens to enhance sensitivity, Quartz, 200-1100nm

SLIT-xx

Slit size, please specify xx = 10, 25, 50, 100, 200 or 500µm

OSF-YYY

Order sorting filter for reduction of 2nd order effects, please specify yyy = 385, 475, 515, 550 or 590nm

OSC

Order sorting coating with 590nm longpass filter for gratings VA, BB and VB, for the AvaSpec-2048

OSC-UA

Order sorting coating with 350nm and 590nm longpass filter for grating UA, for the AvaSpec-2048

OSC-UB

Order sorting coating with 350nm and 590nm longpass filter for grating UB, for the AvaSpec-2048